Some Users have reported issues when importing NGS OPUS Reports into Star*Net.
They may get the following error message: "File has mixed type data ,Importing errors found: No vector file created."
This is because OPUS has recently added two new sections into the report. The new sections added to the report are:
1) ITRF position of base as determined by individual baselines
2) Residuals of position determined by individual baselines from the final position
In order to successfully import the OPUS report:
a) we must open and edit the report file (.txt) in Notepad or any text editor
b) remove section: ITRF position of base as determined by individual baselines
c) remove section: Residuals of position determined by individual baselines from the final position
below is an example file indicated the information that needs to be removed:
Once you have made the necessary changes, Save and you should now be able to import the OPUS report into Star*Net.