Important Note: If you ever experience a crash when using MicroSurvey CAD, when you are asked if you would like to send an error report, please always select Yes to send the report. MicroSurvey and IntelliCAD programmers can use these error reports to help investigate and fix crashing problems that occur within the program, even if it is a problem that is not easily reproducible. Please note the crash reports are not actively monitored for technical support purposes.

Please contact technical support if you experience any problems.


Reported: Sept 02, 2021

Problem: Reactors don't start if you run a command too quickly in a new drawing

Workaround: Wait for the new drawing is completely started and the command line stops loading commands before type in any command in the command bar.

Status: Will be fixed in a future update.


Reported: June 02, 2022

Problem: Add Sheet and Title Block command launches Table Function

Workaround: Run _CUI and rename the TB alias

Status: Will be fixed in a future update.


Reported: August 29, 2023

Problem: Spell Checker not working with multiline text

Workaround: None

Status: Will be fixed in a future update.


Reported: August 24, 2023

Problem: FASTAREA (Fast Area by Selecting Objects) does not display area information and scaling in command line

Workaround: use _AREA (Calculate Area by Point Numbers) or use an older version

Status: Will be fixed in a future update.


Reported: December 11, 2023

Problem: Frequent need for REGEN command - primarily on datasets with large coordinate values.

Workaround: None

Status: Will be fixed in a future update.


Reported: October 9, 2020

Problem: When inserting some blocks using insert command or Automap, an error "Duplicate Record name" is displayed and insertion fails.

Workaround: The issue is caused by the *IPN_INTERNAL layer which MSCAD always creates in order to display IPNs.  In some cases, when the block has the layer (which is normal with MSCAD) this issue arises.  If you have a non-MicroSurvey CAD program you can remove the *IPN_INTERNAL layer from the block, purge the destination drawing, and then reinsert.  1. Open the block in MSCAD.  2. _WBLOCK.  3. Configure the output path and file name.  4. Set insertion units to "undefined"  5. Select all visible elements of the block and select "OK."  This will create a new version of the block without the *IPN_INTERNAL layer.  Replace your old version of the block with this one. 

Status: Will be fixed in a future update.