  • FieldGenius Onboard a Leica Total Station with Captivate

    When FieldGenius is installed onboard a Leica Total Station, such as TS16 / TS60 / MS60, you may come across the following error message: Invalid communication settings for instrument. Port may alread...

  • GS14 to Mesa 2 Using Data Collector Internet

    The following was successful using GS14 Firmware 6.0.0. Later versions of the Firmware (Firmware 6.16) have been tested and WILL NOT WORK. Firmware 6.0.0. is currently the only known supported firmwar...

  • SOKKIA Robotic Total Station iX Series Connection Guide

    This document details the steps to connect and configure FieldGenius to the Sokkia iX series robotic total station. This document is specific to the iX series and FieldGenius version 9.3.24.0. For mor...

  • SOKKIA GNSS GCX3 Connection Guide

    This document details the steps to connect and configure FieldGenius to connect to the Sokkia GCX3 GNSS receiver. The document is specific to the GCX3 and FieldGenius version 9.3.24.0.  Select the lin...

  • SOKKIA GRX2 Connection Guide

    This document details the steps to connect and configure FieldGenius to connect to the Sokkia GRX2 GNSS receiver with a GSM modem. For information on how to configure the UHF radio, refer to the Field...

  • Pairing the SOKKIA RC-PR remote with a Total Station

    Why do you need to pair the RC-PR remote to a Total Station? Users will be required to pair the RC-PR remote to the Sokkia IX, SX, and SRX total stations if they have previously performed a reset on t...

  • GS14 CDMA Configuration

    Activating the GS14 CDMA module so it will work with EVR: To activate the CDMA module in the GS14 so that you can use it as a Network Rover on the Verizon network, you require: A CS20 controller that ...

  • Resetting Sokkia's RC-PR units to connect to SRX,SX, and IX Total Stations

    Why reset the Sokkia RC-PR Remote? In the event the the Sokkia RC-PR remote will not pair with a total station or Bluetooth communication is problematic, resetting the RC-PR initializes the Bluetooth ...

  • Leica GS18 Configuration Guide

    Select the link below to download the configuration guide for FieldGenius 9.3.23.0 or Evidence Reocrder 11.1.23.0 or newer....

  • Nikon or Sokkia Total Station Connection Troubleshooting Guide

    Over the years we have noted which communication parameters allow customers to connect with their Nikon or Sokkia Instruments in FieldGenius or Evidence Recorder when they are using a serial cable.  W...